Lipase optimal range and reference range
Compiled by Alina Radu, founder of Sera, from the published sources below · Last reviewed November 9, 2026
Sera's bands for Lipase:
- Optimal 10 – 60 U/L (10 – 60 IU/L); sufficient 8 – 80 U/L (8 – 80 IU/L); out of range above 80 U/L.
Evidence grade: Published reference interval. A band that primarily reflects a published adult laboratory or population reference interval. It is not necessarily applicable to every assay or laboratory.
All units
| Unit | Optimal | Sufficient | Out of range |
|---|---|---|---|
| U/L | 10 – 60 | 8 – 80 | above 80 |
| IU/L | 10 – 60 | 8 – 80 | above 80 |
Bounded on the high side only — a low result is not treated as out of range. No agreed lower limit: alberta's harmonised interval and medlineplus have none, and mayo's is 13 rather than 8 or 10.
What the evidence says
More specific than amylase and raised for longer, so it survives a delayed presentation. Reference intervals differ several-fold between methods, which is why a mildly raised result has to be read against the interval on the report: Mayo Clinic Laboratories uses 13 to 60 U/L, Alberta's harmonised adult interval is below 80, and MedlinePlus quotes up to 160. Sera's bands end at the Mayo and Alberta upper limits. A low result is not flagged, because Alberta's interval and MedlinePlus set no lower limit and no source gives a low lipase a threshold.
Assay: Results differ meaningfully between platforms and methods. Compare against the interval printed by the issuing laboratory before acting on a borderline value.
Sources
- LPS - Overview: Lipase, Serum — Mayo Clinic Laboratories, 2026 · Laboratory / reference-interval sourceReference interval 13 to 60 U/L. Matches Sera's optimal upper edge of 60; its lower limit is 13, not Sera's 10 or 8.
- Lipase and lactate dehydrogenase (LD) updated reference intervals and implementation of lipase correction factor — Alberta Precision Laboratories (Laboratory Bulletin, 19 September 2022), 2022 · Laboratory / reference-interval sourceProvince-wide harmonised adult lipase interval is below 80 U/L with no lower limit; results differed so much between instruments that a correction factor was introduced. Matches Sera's sufficient upper edge of 80.
- Lipase test — MedlinePlus Medical Encyclopedia, US National Library of Medicine, 2025 · Government / public-health guidanceNormal results are 0 to 160 U/L in general: twice Sera's upper edge and with no lower limit, which shows the method spread.
What Lipase measures
A fat-digesting enzyme produced almost entirely by the pancreas.
More specific than amylase and raised for longer, so it is the better single test for pancreatitis and the one that survives a delayed presentation. Reference intervals vary several-fold between methods, so read a mildly raised result against the interval on the report rather than against a remembered number.
Related liver & pancreas health markers
- ALT (Alanine Aminotransferase)
- AST (Aspartate Aminotransferase)
- FIB-4 Index
- ALP (Alkaline Phosphatase)
- GGT (Gamma-Glutamyl Transferase)
- Amylase
- CK (Creatine Kinase)
- Bilirubin (Total)
- Bilirubin (Direct)
- Albumin
- Total Protein
- Globulin
- A/G Ratio (Albumin/Globulin)
- Alpha-1 Globulin
- Alpha-2 Globulin
- Beta Globulin
- Gamma Globulin